Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 457
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Cateteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem
3.
J Cardiothorac Surg ; 19(1): 53, 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38311759

RESUMO

BACKGROUND: Sinus of Valsalva aneurysm (SVA) is an extremely rare condition, and its rupture causes acute symptoms such as chest pain and dyspnea. Ruptured SVA is frequently associated with other congenital defects. CASE PRESENTATION: A 37-year-old male presented with SVA originating from the left coronary sinus that ruptured into the interventricular septum. SVA was diagnosed by echocardiography, cardiac computed tomography and magnetic resonance imaging, and confirmed during the operation. CONCLUSIONS: SVA is a rare cardiac abnormality which can lead to severe clinical symptoms upon rupture. Immediate surgery is necessary to repair the ruptured SVA.


Assuntos
Aneurisma Aórtico , Doenças da Aorta , Dissecção Aórtica , Ruptura Aórtica , Seio Coronário , Seio Aórtico , Septo Interventricular , Masculino , Humanos , Adulto , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia , Seio Aórtico/patologia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Doenças da Aorta/complicações , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/diagnóstico por imagem
4.
Cardiol Young ; 34(1): 189-191, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38031460

RESUMO

Coronary cameral fistula is a rare congenital anomaly and clinical presentation depends on the location of the defect, degree of shunting, and associated complications. We present a case of coronary cameral fistula where segmental analysis by echocardiogram helped us to avoid misdiagnosis as a ventricular septal defect.


Assuntos
Doença da Artéria Coronariana , Fístula , Cardiopatias Congênitas , Comunicação Interventricular , Septo Interventricular , Humanos , Septo Interventricular/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem
5.
Cardiol Young ; 34(1): 120-125, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37231590

RESUMO

Pulmonary atresia with an intact ventricular septum is characterised by heterogeneity in right ventricle morphology and coronary anatomy. In some cases, the presence of ventriculocoronary connections may promote coronary artery stenosis or interruption, and aortic diastolic pressure may not be sufficient to drive coronary blood flow. This requires a correct evaluation (currently done by angiography) which depends on whether the patient can be offered decompression of the right ventricle. To date, there is no objective method to do so, so we designed a percutaneous, transitory technique with the purpose of occluding the transtricuspid anterograde flow. The manoeuverer was performed in a 25-day-old female with pulmonary atresia with intact ventricular septum, right ventricle at suprasystemic level, and selective coronarography was not conclusive, the anterior descendant with stenosis in its middle third and from this point, thinner with to-fro flow. Occlusion was performed with a balloon catheter. We re-evaluated the coronary flow and the normalised anterior descendant flow. We hope that with this new method, we can give a more accurate diagnosis and determine the cases in which the coronary circulation is truly not right ventricle dependent to offer a greater number of patients biventricular or 1.5 ventricular repairs and thereby improve their quality of life and survival, the ones that turn out to be right ventricular dependant; offer them an early reference for cardiac transplant or in case it is not available to consider univentricular palliation knowing that this probably would not reduce the risk of ischaemia and/or death over time.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Septo Interventricular , Humanos , Feminino , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Ventrículos do Coração , Qualidade de Vida , Resultado do Tratamento , Circulação Coronária
9.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37748089

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. METHODS AND RESULTS: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. CONCLUSION: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


Assuntos
Bloqueio Atrioventricular , Septo Interventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Septo Interventricular/diagnóstico por imagem , Sistema de Condução Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Doença do Sistema de Condução Cardíaco
10.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
12.
BMC Cardiovasc Disord ; 23(1): 346, 2023 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438743

RESUMO

BACKGROUND: Rare as membranous ventricular septal aneurysms (MVSA) is, the possibility that occurs after ventricular septum defect (VSD) repair surgery is even more uncommon. PRESENTATION: A girl developed a MVSA 3 years after the VSD repair surgery at the age of 1 and increasing growth was noted during the follow-up. Aneurysm plication was carried done when she was 11 years old because it was observed to have a close relationship to the right coronary and obstructed the right ventricular outflow tract. Postoperative echocardiography follow-up revealed no abnormalities. CONCLUSION: Though the prognosis of most patients with VSD repaired surgery was good, there remains varieties type of complications despite surgical advances. Accurate and rapid diagnosis of acute and delayed complications is essential to improve prognosis. In this case, the aneurysm was diagnosed by multiple imaging modalities and the girl underwent successful surgery again which provides direction for awareness and knowledge of delayed complications of VSD repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Aneurisma Cardíaco , Comunicação Interventricular , Septo Interventricular , Feminino , Humanos , Criança , Seguimentos , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/cirurgia , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia
16.
World J Pediatr Congenit Heart Surg ; 14(3): 364-367, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36895120

RESUMO

Interventricular septal hematoma is a rare and life-threatening complication of pediatric cardiac surgery. Commonly seen following ventricular septal defect repair, it has also been associated with ventricular assist device (VAD) placement. Although conservative management is usually successful, operative drainage of interventricular septal hematoma occurring in pediatric patients undergoing VAD implantation should be considered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Comunicação Interventricular , Coração Auxiliar , Septo Interventricular , Humanos , Lactente , Criança , Coração Auxiliar/efeitos adversos , Septo Interventricular/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Comunicação Interventricular/complicações , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/cirurgia , Insuficiência Cardíaca/etiologia
17.
Am J Cardiol ; 193: 111-117, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36898244

RESUMO

Described herein are 4 patients who underwent orthotopic heart transplant (OHT) because of heart failure caused by acute myocardial infarcts which healed. These healed infarcts were the result of preferential severe narrowing of the left anterior descending coronary artery. In all 4 cases, the myocardial infarct caused severe scarring of the ventricular septum (VS), more than that observed in the left ventricular free wall where most myocardial infarcts secondary to coronary artery narrowing typically occur.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Infarto do Miocárdio , Septo Interventricular , Humanos , Septo Interventricular/diagnóstico por imagem , Infarto do Miocárdio/complicações , Ventrículos do Coração/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Transplante de Coração/efeitos adversos
18.
Pediatr Cardiol ; 44(6): 1342-1349, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36729238

RESUMO

Up to one third of patients with pulmonary atresia with intact ventricular septum (PA-IVS) will have inadequate anterograde coronary blood flow and rely on fistulous connections from the right ventricle (RV) for myocardial perfusion, known as RV-dependent coronary circulation (RVDCC). Historically, identification of the extent of ventriculocoronary connections and coronary stenosis has required invasive imaging with cardiac catheterization and angiography. Cardiac computed tomography (CCT) potentially provides a less invasive imaging option for therapeutic planning in this group of patients. We describe six neonates with PA-IVS who underwent both CCT and cardiac catheterization at our institution prior to any surgical or transcatheter intervention between 2009 and 2019. Imaging was concerning for RVDCC in all six patients. The average tricuspid Z-score was - 4.19 (2.1 to - 5.34). Two patients underwent cardiac transplantation and two patients underwent ductal stenting. The overall mortality rate was 50%. CCT findings closely mirrored the findings of invasive cardiac catheterization and identified important morphological variations. The average radiation exposure (DLP) per CCT was (10.5 mGy cm, range 6-20). Technological improvements in CCT have enabled adequate visualization of coronary anomalies in children with comparable accuracy to cardiac catheterization, but considerably less radiation exposure. However, diagnosis of RVDCC requires direct right ventricular angiography. Therefore, the potential benefit of obtaining a CCT prior to catheterization for infants with PA-IVS is the ability to risk stratify, assist with procedural planning, and improve family counseling.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Septo Interventricular , Recém-Nascido , Lactente , Criança , Humanos , Angiografia por Tomografia Computadorizada , Resultado do Tratamento , Septo Interventricular/diagnóstico por imagem , Cateterismo Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Circulação Coronária , Estudos Retrospectivos
19.
Europace ; 25(4): 1451-1457, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794652

RESUMO

AIMS: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. METHODS AND RESULTS: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. RESULTS: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68-119) vs. 85 (59-118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). CONCLUSION: The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. TRIAL REGISTRATION NUMBER: jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014).


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Cateteres , Eletrocardiografia/métodos
20.
Eur Heart J Cardiovasc Imaging ; 24(6): 710-718, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36841935

RESUMO

AIMS: Echocardiographic diagnosis of left ventricular outflow tract obstruction (LVOTO) in hypertrophic cardiomyopathy (HCM) often requires extensive provocative manoeuvers. We investigated, whether echocardiography-derived parameters obtained at rest can aid to determine the presence of LVOTO in persons with HCM. METHODS AND RESULTS: Consecutive patients with HCM admitted to a referral centre underwent standardized transthoracic echocardiographic examination including provocative manoeuvers. Under resting conditions, the length of mitral leaflets and distances between mitral valve coordinates and ventricular walls were blindly measured in parasternal long axis (PLAX) and apical three-chamber (3ch) views, both at early and late systole. Among 142 patients (mean age 59 ± 13 years, 42% women), 68 (42%) had resting or provocable LVOTO with maximal LVOT gradients ≥30 mmHg. Late-systolic distance between mitral leaflet tip and ventricular septum (TIS) was measurable in 137 participants (96%) in 3ch view and independently associated with LVOTO in multivariable logistic regression analysis. The area under the ROC curve of TIS for the identification of LVOTO was 0.91 [95% confidence interval (CI) 0.87-0.96]. TIS ≤ 14 mm yielded 97% sensitivity and 57% specificity regarding LVOTO. TIS >14 mm ruled out LVOTO with a negative predictive value of 95%. TIS ≤9 mm ruled in LVOTO with a positive predictive value of 92% (sensitivity 73%, specificity 95%). Among 43 patients with TIS between 10 and 14 mm, 35% had LVOTO. CONCLUSION: In our study, the novel echocardiographic parameter TIS showed high negative and positive predictive values for LVOTO in HCM. These exploratory results await confirmation in larger collectives and prospective investigations.


Assuntos
Cardiomiopatia Hipertrófica , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Septo Interventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Septo Interventricular/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Ecocardiografia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...